- Coated CCD detection system
- Roller press CCD detection system
- Roller Slitting Machine CCD Detection System/Labeling Machine
- Pole slice CCD detection system
- Independent wide CCD re-inspection machine
- Tab forming equipment CCD system
- Electrode burr detection
- Power battery winding machine CCD detection system
- Cutting and stacking machine CCD detection system
- Power Bare Cell Appearance Inspection Machine
- Power battery casing equipment/pre-spot welding
- Power battery top cover welding inspection machine
- Power battery sealing nail detection system
- Inspection of the front six sides of the blue film of the power battery pack
- Power battery aluminum shell, blue film appearance inspection machine
- Finished battery appearance inspection machine
- Power battery connector welding detection system
- Blade Battery Measurement Dimension Measuring Machine
- Power battery module Busbar testing machine
- Power battery module size detection
- Small power battery automatic FT test and air tightness testing machine
- Copper foil appearance inspection
- Aluminum foil appearance inspection
- Diaphragm appearance inspection
- Aluminum plastic film appearance inspection
- Visual inspection of cylindrical aluminum shell
- Appearance inspection of square aluminum shell
Roller press CCD detection system
Inspection and Calibration
· Spot check and calibration: Remind the spot check at the set time, if the check is not passed or the machine is locked if the check is not overtime.
· Defect spot inspection: Black dot film is used for spot inspection, which is pasted on the roller shaft.
· Size inspection: Black rectangular film is used for inspection, and the inspection sheet is pasted on the roller.
Automatic GRR
· According to the nested GRR mode, automatic GRR is developed. The software selects the automatic GRR mode, and after the data is collected, the CVS file is automatically generated.
Fool-proof function
· The CCD detection is not running, and the slitter cannot run.
· The software monitors key steps, and if there is any abnormality, it will alarm and stop.
· Key parameter changes are recorded in log files.
· After changing the material, the membrane roll number must be changed; if it is not changed under special circumstances, the advanced authority must be enabled.
· If there are more than 3 bad products in a row, the alarm prompts the staff to confirm the condition of the pole piece and check whether the CCD lens is contaminated.
· If the marking is abnormal, it will alarm and stop and prompt.